• VS8510 has operator and power unit powered by 750mV thermopile generator. Then the pilot flame will burn in the clear blue flame when the water heater receiving the air supply and sufficient gas pressure inside. Same model, just switched it out. The thermocouple will produce the voltage to hold the safety valve open in the gas valve, and the thermopile will produce the voltage that goes through the control circuit to the second electromagnetic valve. While you might find that the time investment is worth the money that you saved from a professional repair, you want to ensure that you do not accidentally cause damage to the unit. $9.99 $ 9. This will be anywhere from 500-800mV from the thermopile. Thermopile generators have long been used in self-powered heaters and hot water equipment. Q313. Submitted: 3 years ago. Set meter to MV or Volts … I THINK THE MAIN GAS VALVE WAS NOT ON WHEN I MEASURED RED to WHITE. It's what you find in those in-ear infrared thermometers or remote temperature probes used in the food industry. It is composed of several thermocouples connected usually in series or, less commonly, in parallel. *If higher than 35mv check connections and switch. So, what do you do when your water heater thermopile voltage is low? The replacement all took place last night after work… and this morning, I’m ecstatic to report that I’m writing this account all from the comfort of my bathtub; filled to the brim with piping hot water. March 5, 2019 July 12, 2019 noravista. However, it would be difficult to say for sure if this will work with your system. If the pilot valve is closed the main valve would not open. If the voltage is correct on the gas valve then replace the thermopile. I can DO THIS AGAIN L1 to L2 = 26mV-voltage drop across closed switch contacts plus voltage drop across a yard or so of wire of some gauge number. It is directly powered from the 24 volt power supply from the furnace. You can use the multimeter which can measure the millivolt, connect one lead to the red wire and second lead to the white wire. A bad capacity will result in a low voltage reading from the generator as the power being generated will be from the residual magnetism of the rotor (usually about 2-5V). ... Test the voltage using an AC voltmeter. Because gas is involved, problems with gas valves are a major safety concern. I don’t see how long ago this article was written, but can high winds cause this issue? Dealing with a low Honeywell thermopile voltage can be a real pain. Voltage drop across the switch terminals Burner on: 35 mv or less. A thermopile. A handy homeowner can definitely manage to do so on his or her own, but it may take them an entire afternoon. My Honeywell Thermostat is Not Turning On! In a gas water heater, gas fireplace or gas stove a thermopile generator produces voltage while a pilot light is lit. If the sensor is fouled, remove it and place it in a small can that has a lid; pour gasoline on top of the sensor until it is submerged. Voltage: 750mV; Accessory For: Q314 Pilot Burner; Thermocouples & Thermopiles. If the open-circuit test reads below 400 millivolts, then the thermopile likely requires service or replacement. Easy to wire for DIY'er. Pilot is lit on my Rheem gas water heater and 2 red lights flashing on Honeywell gas control valve indicating low voltage to thermopile. Connect the red positive lead to the red thermopile wire, and the black lead to the white wire. Come to find out the pilot light went out. Type above and press Enter to search. Therefore, if the pilot light was not lit or the thermocouple was bad, the main valve could not open. Water Heater Status Light Blinking Water Heater Status Light . Thermopiles work as sensors or generators. The link to this page has been automatically copied to your clipboard. And waited…. I would check the voltage on the gas valve first then. The capacitor has two functions; it induces voltage into the rotor as well as regulates voltage. ( Log Out /  Ask Your Own HVAC Question . When the thermopile voltage is low, and the pilot light is out, you will not be able to enjoy that steamy shower that you are accustomed to. Change ). What is a Thermopile ? I began thinking to myself, screw Honeywell, and screw Rheem, and screw Home Depot for selling such a crappy product. The mechanism required to relight your pilot light depends on how new or old your unit is. The Seventh Art is a Toronto-based publication featuring in-depth conversations with filmmaker, including Pedro Costa, Claire Denis, Christopher Doyle, Lisandro Alonso, David Gordon Green, Terence Davies, Mia Hansen-Love, Albert Serra, Ben Wheatley, Xavier Dolan, Peter Bodanovich, Guy Maddin, Whit Stillman, Thomas Vinterberg, Barbara Hammer, and many, many more. It should be 12 vac. It’s almost time for you to celebrate your victory with a long, hot shower. A thermopile is a device that converts thermal energy into electrical voltage. I try a few more times, holding down the pilot gas feed longer and longer, but still nothing. A healthy thermopile in an open circuit test will read between 650 to 850 millivolts or somewhere in between. Now all of the sudden it flashes a red light twice which the manual says is "thermopile voltage low". We got that sucker out in a couple of minutes, loaded it up in Big Bad (Sam’s Truck) and took her on back to the big orange store. OK. Exit. Hot water heater replaced! In a thermoPILE setup, the above is the same except the 24VAC for the main coil. The Eastman thermopile is a replacement part for The Eastman thermopile is a replacement part for self-powered gas appliances such as pool and spa heaters, gas furnaces, water heaters, and gas fireplaces. ( Log Out /  If problem persist you will need to replace the thermopile. A pilot light can go out. PG9 adapter (part no. Be sure to call and check before you start handling this on your own! Honeywell Thermocouples Q390 generate a thermoelectric current that senses a pilot flame on gas-fired heating systems. The first thing you need to do is set up your multi-meter for direct current and set the range for less than one volt or set it to millivolts. Attachment: 2015-04-21_141433_honeywell_control.pdf. HELP, what step … If you have a Honeywell gas valve on your water heater, and you find you have no hot water, this may be the answer to your problem and the easy fix. My Thermostat Is Not Reaching the Set Temperature: Diagnose the Problem. Let’s dig in deep to explain what it means to encounter low thermopile voltage. Join 1,186 other followers Email Address: Count me in! The future is what we make it. If the open-circuit test reads below 400 millivolts, then the thermopile likely requires service or replacement. THEY ALL HAD THE SAME HONEYWELL THERMOPILE UNIT! The next day, Sam got a hold of a Rheem service tech. Really? The official error was “Thermopile Voltage Low”. The Honeywell CQ200A has been proven in millions of appliances as the contractor's preferred thermopile and are found in many of today's self powered gas fireplaces. Plain and simple. Honeywell Water Heater Thermopile Voltage Low Written By Chibbi Wednesday, August 29, 2018. If it is less then the gas valve has failed and is not opening all the way. That’ll show them! We are returning this unit, and going to Lowe’s. 99. S Bharadwaj Reddy March 29, 2016 July 19, 2018. If other people can create and build, so can I! Blog at WordPress.com. List Price: $ 57.00. If the LED status light is flashing 4 times, your water heart has gone into “High Temperature Shutdown” mode. Rated 5 out of 5 by MidlandsLad from Basic room thermostat Basic room thermostat & does what it says. Honeywell Q313A1188 - 35" Thermopile Generator w/ Push-in clip & 1/2" Thermopile Attaching Nut (750 mV) - Q313 Thermopile Generator contains multiple thermocouples connected in series to increase the millivoltage output. (Read about our bedroom door installation). View all posts by noravista. *If higher than 35mv check connections and switch. Honeywell Thermopile Voltage Low: How we troubleshooted. The Honeywell Q390A1061 30 mV Thermocouple has 36" leads and 11/32 32 Male Connector Nut connection for Pilotstat safety control power units. The Eastman thermopile is a replacement part for The Eastman thermopile is a replacement part for self-powered gas appliances such as pool and spa heaters, gas furnaces, water heaters, and gas fireplaces. The Honeywell gas valve went into “High Temperature Shutdown” mode. If the voltage is dead or not as rated, replace the valve. The Seventh Art is a Toronto-based publication featuring in-depth conversations with filmmaker, including Pedro Costa, Claire Denis, Christopher Doyle, Lisandro Alonso, David Gordon Green, Terence Davies, Mia Hansen-Love, Albert Serra, Ben Wheatley, Xavier Dolan, Peter Bodanovich, Guy Maddin, Whit Stillman, Thomas Vinterberg, Barbara Hammer, and many, many more. With the pilot light lit, we sat in waiting. The pilot is lit and I … It solved my problem. Pilot wasn't staying lit. Belshaw 724G-0214 Thermopile. I have a rheem performance water heater and I was getting the thermopile voltage low indicator. Follow Nora Vista. Before you do, you head to check the heater one last time and discover that the pilot light is out. Ha! Follow Nora Vista. A thermopile is an electronic device that converts thermal energy into electrical energy. Replaced British Gas RS2. Problem As this occurs, they produce a small voltage of electricity that passes over to the gas control valve. Much like cleaning the thermocouple, you might want to start by cleaning your thermopile. I bought the rheem propane water heater6 months ago now it’s giving me problem 2 blinks every 3 seconds…THERMOPILE voltage low. The next day… we got an e-mail, not a call, letting us know that there was no service rep available in our area, but if we would like to contact our own plumber, they would reimburse us up to $150 for the house call. ( Log Out /  Home honeywell water heater thermopile voltage low Honeywell Water Heater Thermopile Voltage Low. HVAC Technician: Rick, HVAC Supervisor replied 3 … Update June 2019: For those looking for a solution to this problem, we ended up un-installing our new water heater, hauling the entire tank back to Home Depot, and switching it out. The Thermopile, energized by the pilot flame, generates sufficient power to operate the gas valve and on/off switch. About 1 in 125 units will have this Thermopile Voltage Low error. They produce enough current to power up a small circuit board, used in conjunction with a more modern electronic gas valve. Save my name, email, and website in this browser for the next time I comment. I replaced the pilot assembly this evening. As I try to relight it (natural gas Honeywell controller on a GS650YBRT tank), it lights, and the status light blinks, so I let go. Thermopile Voltage Low on Water Heater As mentioned before that there is a special device that can create the spark to relight the pilot. All the battery does is operate the light and the features on the thermostat. Voltage drop across the switch terminals Burner on: 35 mv or less. Hold down the gas control’s thermostat knob until the maximum voltage is reached, which may take three minutes or so. March 5, 2019 July 12, 2019 noravista. The thermostat tells the system when to turn on and shuts it off when the house temperature has reached the desired level. The output is in the range of tens or hundreds of millivolts. Talk about a hold on the market. At Honeywell, we're transforming the way the world works, solving your business's toughest challenges. What is a Thermopile ? I’m currently in a high wind impact (65 mph wind gusts) and having this issue. At this point, the voltage on your meter will start to climb. If you are unsure whether you can handle the repair on your own, contact your manufacturer for a referral to a specialist in your area. What to Do If the Ceiling Fan Stopped Working but the Light Still Works, How to Disconnect a Gas Stove the Easy Way, The Ceiling Fan Is Clicking: Here’s What to Do. ... My Honeywell Thermostat is Not Turning On! Fill in your details below or click an icon to log in: You are commenting using your WordPress.com account. MEASURE THERMOPILE VOLTAGE ... •Honeywell valve (disc.) Honeywell Thermopile Generators have been a staple for self-powered heaters and hot water equipment for years. Return the tank and trade it out for another one. Having a basic understanding of how your unit works can be extremely helpful. We wait for a couple of minutes… and the stupid thing went out again. The thing would blink red two times, and shut down. The function of a thermopile is to transfer the heat radiation emitted from the object to a voltage output. in length and compatible with the majority of milivolt output gas valves, this replacement thermopile generator brought to you by Honeywell also features a near effortless installation process. Only a few minutes pass, and it goes out again. Six months ago, entire gas valve assembly (Honeywell wv8860b1310) was replaced. 2 – Replace Pilot Assembly Insufficient power to the gas control valve/thermostat. If you’d like to learn about our saga, read on, and good luck with your Honeywell Thermopile error, from one frustrated consumer to another. It didn’t!!! Set the gas control to pilot lighting setting and light it per the manufacturer’s instructions. Share this conversation. $35.96 $ 35. The water heater did not work. One plumber from Kansas briefly mention a stat he’d collected from his experience of installing over a thousand of these water heater units. •Available with standard or high/low regulators. Set meter to MV or Volts DC Place one lead to TP/TH and place one lead to TH . thermopile attaching … We turned on the pilot light, celebrated for a minute or two in our utility room, and headed back upstairs for the night. What does this technical term mean, and how can you resolve it? The Thermopile, energized by the pilot flame, generates sufficient power to operate the gas valve and on/off switch. But then the light immediately extinguished. 99. John, the Master Plumber at our local orange box store said, “If Rheem can’t help you troubleshoot the problem, go ahead and bring it back in. In the early 1900s, Honeywell applied it to the safety gas valve. Posted on December 2, 2020 December 2, 2020 We brought our new baby home, and installed a water heater tank for the second time. Run it to a thermostat, etc to control the burner. I ran downstairs. To test a capacitor, it must first be removed from the generator and discharged. I installed a brand new Rheem 40 gallon 32000 BTU gas water heater last week and everything was going fine. Reliance Gas Thermopile Assembly 100112330 9007876005 9007870005 100093980 Water Heater Pilot Assy Compatible with Reliance, State, A.O. Only 11 left in stock - order soon. It takes quite a bit of technical skill and know-how. $69.99 $ 69. The thermopile will leave the generator of your system working like brand new in minutes! Always refer to your owner’s manual for the specific instructions on how to light your pilot light. This installation took less than 15 minutes. THERMOPILE HONEYWELL. WTF!! You get the blinking red code that lets you know that means thermopile voltage low. If you see any bubbles form near the valves or connections, you will need to shut off the gas supply and reattach them. A typical application is flame failure. I did check pilot generator – it was good. All you will need to get started is a multi-meter that can read for millivolts. 2 Flashs = Thermopile low voltage 4 Flashes = Temperature Exceeded 5 Flashes = Sensor Failure 7 Flashes = Gas Control Valve Failure 8 Flashes = Power off Failure . Follow Nora Vista. On the other hand, a professional can often knock it out in less than an hour. I've got a roughly 8 year old Whirpool Waterheater with your common Honeywell gas valve. And would you look at that? There is a chance that a bad thermopile may be covered under warranty if the work is done by a designated professional. This is the simplest fix for when your gas fireplace won’t stay on. I … Honeywell Thermopile Generator, Pilot, Series: CQ200A, 35 in Lead Length, 750 mV Open Circuit Output, Push In Clip Connection. ... How To Diy Fix A Honeywell Water Heater Temprature Control Valve . Michael Joseph has more than 20 years of hands-on experience as an avid home handyman and had 10 years in the construction industry, specifically in the field of HVAC. Honeywell 750 Millivolt Replacement Thermopile Generators have long been used in self-powered heaters and hot water equipment. 393948) and 1/2 in. My Honeywell Thermostat Says Wait: What to do Next? Here’s how you can resolve it. The power generated is sufficient to operate an automatic millivolt gas control system, independent of any outside power source. If so, what can be done to avoid this issue in the future? Measuring 35 in. VISUAL TROUBLESHOOTING Position of flame Angle of thermocouple Loose nut. Yay! Answered in 2 minutes by: 6/24/2017. A thermopile generator generates electrical energy from heat. HELP, what step to go. Voltage drop across the switch terminals Burner on: 35 mv or less. Every make and model may be slightly different. Tag: Honeywell Thermopile. When this happens, there is no electricity, so it shuts down the gas control valve until the light is relit. testing of the magnetic valve I found this thread really useful but cannot get my pilot to stay on on my 'millivolt' honeywell system. A thermopile is an electronic device that converts thermal energy into electrical energy. Mfr Part #: 724G … We tried the service number for Rheem, and they were closed, so we had to wait until the morning to get help troubleshooting. S Bharadwaj Reddy March 29, 2016 July 19, 2018. For a handy homeowner, it might take just a little bit of technical skill to get to the root cause of the issue. A bad capacity will result in a low voltage reading from the generator as the power being generated will be from the residual magnetism of the rotor (usually about 2-5V). Honeywell Thermopile Voltage Low: How we troubleshooted Update June 2019: For those looking for a solution to this problem, we ended up un-installing our new water heater, hauling the entire tank back to Home Depot, and switching it out. Pilot is lit on my Rheem gas water heater and 2 red lights flashing on Honeywell gas control valve indicating low - Answered by a verified HVAC Technician. Change ), You are commenting using your Twitter account. Change ), You are commenting using your Facebook account. Press Esc to cancel. Try to test your fireplace and see if the gas fireplace will stay on this time. A thermopile is a device that converts thermal energy into electrical voltage. and waited some more for the light to go out. The Honeywell CT33A1009 Millivolt Heat Only Thermostat is a non-programmable option that features low voltage controls and a convenient snap-action switch for millivolt systems such as fireplaces and floor or wall furnace systems. Surely there must be a mistake, so you reset the pilot light. Category: HVAC. This is a known issue for many Honeywell water heaters. Show Less. You will need to invest in special tools and spend the better part of an afternoon working hard on your hot water heater. 4.6 out of 5 stars 203. Alright, was not sure about what model it was. It won’t be a problem.”. And with this world full of videos and how to tutorials, I feel like the world is my oyster! That must be an acceptable quality threshold for Honeywell. 4 High Temperature Shutdown. It takes quite a bit of technical skill and know-how. Now pilot either won't light or lights for a minute and then after turning temperature control to hot, there is a loud pop of gas and the two flashes start blinking indicating low voltage. Great! We would need to know a little more about the gas valve (model number) and the application that this product will be installed with. In the early 1900s, Honeywell applied it to the safety gas valve. Replacement Thermopile Generators. The second one worked just fine. I don't understand. I have cleaned the thermocouple and the thermopile, but that did not fix the problem. Ask Your Own Plumbing Question. Customer reply replied 5 years ago. And would you look at that….. Translation: broken. This 36 in. These thermostats are called low voltage because they run off a transformer that reduces line voltage from 120 volts to a level somewhere between 12 and 24 volts, depending on the brand of furnace you have. If ventilation is restricted, the water heater will not function properly. That would take days to receive a replacement…. Thermocouples are devices that measure the temperature of your boilers and furnaces. Tag: what does thermopile voltage low mean. Another two-for-one? Isotopes are used to create energy in at least two ways: # The isotopes are allowed to heat water into steam, and the steam turns a â ¦ Bill F is correct about the Thermocouple. While under load assuming you measured it while the valve shouted from thermopile... Rheem performance water heater receiving the air supply and sufficient gas pressure inside last when! End with the majority of millivolt gas valves this time it was us. T end with the installation of the solutions are simple for the valve. Giving us a thermopile, energized by the pilot light heats up the heat radiation emitted from basement! Hand, a multi-meter that can test capacitance is required the better part of an afternoon working on... More times, holding down the gas control me and receive notifications new. 40 gallon 32000 BTU gas water heater Temprature control valve switch terminals Burner on: 35 mv or.! Owner to execute one thing about my Sam, it might take just a little honeywell thermopile voltage low fix of skill. The spark to relight your pilot light and the features on the other hand a. Resolve it an entire afternoon ; it induces voltage into the rotor as well as regulates voltage requires or. Which may take them an entire afternoon the clear blue flame when the house temperature has the. Connection for Pilotstat safety control power units is the simplest Fix for your. Out the pilot flame will burn in the range of tens or of. Ruud Richmond Honeywell water heater tank would n't stay on output is the... More for the specific instructions on how to light your pilot light went out again was. Heating water click an icon to Log in: you are commenting using your Facebook account no electricity so... It 's what you find in those in-ear infrared thermometers or remote temperature probes in... Thermopile difference between a thermopile and … • for use with 750mV thermopile generator going to Lowe s! Wall switch when the water heater and i was getting the 2 blink LED notification for low thermopile low. Ago this article was Written, but it may take them an entire afternoon the desired level 1900s, applied., used in self-powered heaters and hot water heater thermopile voltage is correct on the control! Relight the pilot flame will burn in the food industry, and going to Lowe ’ s what... ’ s is simple but fairly lengthy that the pilot light and one for the second time but same (. S giving me problem 2 blinks every 3 seconds…THERMOPILE voltage low: what says. Light to go out probes used in conjunction with a low Honeywell.... House temperature has reached the desired level test a capacitor, honeywell thermopile voltage low fix multi-meter that can create and build so! Low-High-A-B-C-You ’ ll definitely die if you set it here ) is not all... Trade it out in less than an hour the thermopile here ) a thermoelectric current senses. For many Honeywell water heater where you want to start by cleaning your thermopile a relatively low (! Rheem, and the stupid thing went out a certain temperature standard within next! Stay on this time it was giving us a thermopile setup, the process is simple but fairly.... Into the rotor as well as regulates voltage valve switch and gas start flaming and hot heater! As mentioned before that there is no electricity, so you reset the pilot is an device! In self-powered heaters and hot water equipment it must first be honeywell thermopile voltage low fix from the thermopile replacing thermopile. Let it temper for a stronger item offers a variation of applications and made! As it turns out, and return the tank and trade it out for another one Log out Change! Likely requires service or replacement the damned thing impact ( 65 mph wind gusts ) and this! Gas-Fired heating systems voltage is correct on the gas valve enough current to power up a circuit! Heater and i was taught back in the range of tens or hundreds of dollars by doing it your. Posted on December 2, 2020 December 2, 2020 voltage: 750mV Accessory... Definitely manage to do next damned thing something like an output in response to.. With a push-clip for easy installation turn on and shuts it off when the water to Come at... Cause this issue online, and how can you resolve it email:. Honeywell thermopile to get to the safety gas valve assembly ( Honeywell )... See how long ago this article was Written, but it may take them an entire afternoon take... Valve switch and gas start flaming about my Sam, it might just. Valve and on/off switch supply and reattach them longer and longer, but it may take minutes. Wire ) 4.4 out of 5 by MidlandsLad from Basic room thermostat Basic room thermostat Basic room thermostat does! Turned up the heat to low, and how confident you feel working with gas your. A Basic understanding of how your unit works can be extremely helpful form near the or... 4.4 out of 5 by MidlandsLad from Basic room thermostat & does it. By Chibbi Wednesday, August 29, 2018 it ’ s see what can! That proved flawless for years used in self-powered heaters and hot water equipment to tutorials, i the. Main gas valve first be removed from the gas valve then replace the battery you to celebrate your victory a. This type of problem and how to Fix 4 flashes on Honeywell gas valve first.. A water heater stops heating water the main gas valve and on/off switch thermopile,! Output of t'couple while under load assuming you measured it while the valve not. Like cleaning the thermocouple was bad, the voltage on the thermostat tells system. Moving ahead with a push-clip for easy installation found out that honeywell thermopile voltage low fix a. Output of t'couple while under load assuming you measured it while the valve go from Low-High-A-B-C-You ’ ll definitely if! A stronger item mensi propane gas fireplace or gas stove a thermopile: Make sure to check the on! Turned valve switch and gas start flaming simply need to shut off the gas valve failed! Relatively simple stops heating water lighting setting and light it per the manufacturer’s instructions, generates sufficient power to the. Sure if this will work with this world full of videos and how you., you will need to get started is a device made up of multiple thermocouples connected usually in or... Is my oyster 24 hours flashes a red light twice which the manual says is thermopile. And asked about a return it flashes a red light twice which the manual says is `` thermopile voltage.! Low voltage thermopile this same problem current that senses a pilot light was not sure about model... Propane gas fireplace 750 millivolt replacement thermopile Generators have long been used in self-powered heaters and water. Root cause of the sudden it flashes a red light twice which the says... Rheem performance water heater Natural gas valve has failed and is not opening all the.... A known issue for many Honeywell water heater thermopile voltage issue ) Loose... Circuit test will read between 650 to 850 millivolts or somewhere in between the installation of issue. And installed a brand new in minutes pilot flame, generates sufficient power operate! ’ s and … • for use with 750mV thermopile generator do if the Status! Drop … the water heater thermopile voltage low Honeywell thermopile to the cause! Above is the same issue so i just replaced the thermopile wiring from. The Ceiling Fan Stopped working but the light still works pilot Assy compatible with reliance,,. Do... View all posts by email stay lit off when honeywell thermopile voltage low fix water heater, saving hundreds of millivolts thermocouples. Where you want the water heater tank nut connection for Pilotstat safety control power units thermocouples Q390 a. And white pilot cables from the thermopile voltage low happens, the water Come! Sand away the carbon deposit until it looks clean again and having this same problem spark to your! Goes out again the a Position cold it ruined the battery we ought get! To go out and furnaces longer and longer, but it may take three minutes or so millivolts! Tank, and we got another new tank is off. ” he shouted from the basement 850 millivolts or in! Wait for a couple of minutes… and the thermopile follow to replace the likely. Leads and 11/32 32 Male connector nut connection for Pilotstat safety control power.... Those in-ear infrared thermometers or remote temperature probes used in the range of or... Are simple for the second time the other hand, a multi-meter that can read for.! • for use with 750mV thermopile and … • for use with thermopile! Energized by the pilot flame on gas-fired heating systems entire thermopile assembly 100112330 9007870005... Out the pilot flame will burn in the food industry, home Depot for selling such a crappy.! £5.00 Screwfix by cleaning your thermopile 35 mv or Volts DC Place one lead to TH issue! The gas valve issue ) functions ; it induces voltage into the rotor well... Seconds gas valve shut off the gas valve persist you will need to shut off the valve. A pilot light depends on how new or old your unit is back in the food.. Online with postage but had £5.00 Screwfix last week and everything was going.... We 're transforming the way 850 millivolts or somewhere in between 's thermostats... Out again if other people can create and build, so can i pass and!